DualRunners – Communication Protocol v1.3 - 33 -
Data Capture
for Workforce
in Motion
2.4.6. Examples
Here are some examples to illustrate each type of frame to be sent to the decoder and the possible
answer from the decoder.
2.4.6.1.
2.4.6.1.2.4.6.1.
2.4.6.1. Get Config
Get ConfigGet Config
Get Config
Example 1.1 – Getting configuration of Code 39 symbology.
Frame to be sent to the decoder:
‘E’ ‘A’ 0 -
The decoder answers the following frame:
‘E’ ‘A’ 4 $01 , $05, $06, $20
By reading this answer frame, we can check that the decoder has well understood the selected
symbology (header "E"). The command field contains the configuration itself:
Checksum transmission Disable
3
rd
byte : Min length = 6
4
th
byte Max length = $20 = 32
Comentários a estes Manuais