Baracoda ToughRunners Manual do Utilizador Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 26
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
Communication Protocol for Baracoda ScanWear/ToughRunners Scanners
Sept. 07 19/26
Command Header Length Payload Answer
Get page scan
timeout
0x25 00 00 - 0x25 00 04 [Page Interval (MSB) | Page
Interval (LSB) | Page Window (MSB) |
Page Window (LSB)]
Page Scan Interval and Page Scan Window are in number of Bluetooth slots) (1 slot =
0.625 ms)
Command Header Length Payload Answer
Set page
scan
timeout
0x24 00 04 [Page Interval (MSB) | Page Interval
(LSB) | Page Window (MSB) | Page
Window (LSB)]
(default 0x320, 0xb0)
0x24 00 01 01 if
done
0x24 00 01 00 if
not
Page Scan TimeOuts are used by the Module to answer to Connect Inquiries. So, if you
set both values to 0, the Module will not be Connectable.
Typical values are:
Full power:
Inquiry Interval = 0x400
Inquiry Window = 0x200
Page Scan Interval = 0x400
PageScan Window = 0x200
Low power:
Inquiry Interval = 0x320
Inquiry Window = 0x80
Page Scan Interval = 0x320
PageScan Window = 0x80
Here is how these values change the consumption of the Module:
Command Header Length Payload Answer
Set sniff 0x09 00 04 [MSB of MinSniff interval, LSB of MinSniff
interval, MSB of MaxSniff interval, LSB of
MaxSnif interval]
0x09 00 01 01 if
done
0x09 00 01 00 if
not
Command Header Length Payload Answer
Set sniff
(advanced)
0x09 00 08 [MSB of MinSniff interval, LSB of MinSniff
interval, MSB of MaxSniff interval, LSB of
MaxSnif interval,
Sniff Attempts MSB, Sniff attempts LSB,
Sniff timeout MSB, Sniff timeout LSB]
0x09 00 01 01 if
done
0x09 00 01 00 if
not
(default 0xf0, 0x50, 0x08, 0x08)
Page Scan and Inquiry Scan Interval
Page Scan
Window
Inquiry Scan
Window
Vista de página 18